Ophthalmological instruments

圖片_眼科儀器_眼睛內的光散射量_HD Analyzer
Figure 1
圖片_HD Analyzer_眼科儀器_光散射量
Figure 2

HD Analyzer

The HD Analyzer is a precision instrument that quantifies the amount of light scattered within the eye, providing us with an objective measure of visual quality. This is useful for evaluating cataracts because it can tell us the severity of the cataract and its impact on vision. It can also objectively assess dry eye by measuring the stability of the tear film, which plays a role in tear production. By comparing the stability of the tear film over time with the eye’s scatter, the impact of dry eye on visual quality can be evaluated. This helps to rule out abnormal tear membranes that cause vision loss and can also be used to monitor a patient’s response to dry eye treatment.

圖片_眼科儀器_5合1工具_視力評估質量_瞳孔大小_Itrace

iTrace

It provides a 5-in-1 tool for eye health to analyze complete visual function. It can be used with an easy-to-use device to measure the patient's wavefront, corneal topography, pupil size, refractive index, and corneal curvature, thereby providing a comprehensive assessment of visual quality.

圖片_眼科儀器_角膜表面_Scheimpflug層析成像

Sirius +

The corneal topography combines the Praxidopteran intervertebral disc topography and the anterior Scheimpflug layer imaging, providing information on the thickness, height, curvature, and refractive index of the two corneal surfaces with a diameter of 12 mm. All biophysical measurements of the anterior chamber are calculated using up to 100 HR corneal slices.

圖片_AngioVue OCT​_通過無創_無熒光造影_眼科儀器

AngioVue OCT

Using non-invasive, non-fluoroscopic imaging techniques to quickly test the patient’s microvascular system, the technology can be performed by trained technicians in seconds. With AngioVue, you can image the patient as needed to closely monitor disease progression and treatment response.

 
 
IMG_6158

Optovue Epithelial Map

The proprietary epithelial thickness chart is the first non-contact quantitative measurement of corneal epithelium and stroma. It can help you assess early changes in the cornea to help diagnose corneal diseases. A quick two-second scan identifies areas of thickening or thinning associated with dry eye disease, cone-shaped cornea, or previous refractive surgery. The change analysis allows you to track the changes in the ETM map over time, thereby evaluating the efficacy of cross-linking or dry eye treatment. For patients undergoing refractive surgery, the ETM provides a reliable risk analysis by quantifying the thickness of epithelium and stroma, which can change the surgical plan or help you evaluate the results of refractive surgery.

OSA dry eye test

OSA effectively integrates the following complex examinations, providing users with dry eye results reports:

  • Orbital gland imaging with contrast
  • Demodex imaging
  • Orbicularis Oculi Imaging
  • NIBUT tear splitting time
  • Fatty layer assessment
  • Eye level tears

Laser machine

  • Laser treatment of retinal holes
  • Laser removal of glass floaters
  • Cloudy gallbladder after laser removal
  • Laser prevention of acute angle-closure glaucoma
圖片_眼科儀器_激光機​_視網膜孔
圖片_OPTICAL COHERENCE TOMOGRAPHY_光學相干斷層掃描​_青光眼_黃斑

OPTICAL COHERENCE TOMOGRAPHY
Optical coherence tomography

Optical coherence tomography (macula)

  • The macular retinal tomography scans the cross-sectional structure of the macular area.
  • Check for various macular lesions, such as macular edema, macular tear, macular age-related disease, diabetic retinopathy, and the anterior vitreous membrane.

Retinal optical tomography (blue light retinopathy)

  • Examination of the thickness of the optic nerve head and computed tomography
  • Check the thickness of the retinal nerve fiber layer and the cup/disc ratio of the optic nerve plexus
圖片_眼科儀器

SLIT LAMP

  • Examine the conjunctiva, anterior chamber, iris, eyelids, vitreous body, retina, macula, and optic nerve of the eyes.
  • High-resolution digital images, still photography, and video recordings help patients and their families understand the condition.
  • The slit lamp is usually composed of two parts: the light source and the binocular microscope, that is, the illumination system and the observation system.
  • The light source refers to the beam of light in the instrument that can be adjusted in width and height according to the illumination requirements horizontally and vertically. At the same time, the binocular microscope focuses on the same location or plane illuminated by the light source, which is also the process of combining the two parts.

  • Use slit-lamp microscopes to examine the eyelids, the cornea, the iris, the anterior chamber, the vitreous body, and the retina.

圖片_眼科儀器_眼壓及角膜弧度測量儀_自動測量

Eye pressure and corneal curvature measuring instrument

  • Basic visual acuity, eye adjustment ability, and post-illumination image can be measured.
  • 3D full-automatic focus and automatic measurement
圖片_VISUAL FIELD_眼科儀器_視野圖測量儀​

VISUAL FIELD Viewfinder measuring instrument

  • In the background illumination fixed to the instrument, the sensitivity of the retina to different locations of the light spot is measured.
  • Visual field testing is primarily used to diagnose glaucoma and other eye diseases that can lead to visual impairment. It helps doctors diagnose and track the progression of the condition and prescribe appropriate treatment.
WhatsApp Image 2019-11-25 at 12.36.44 PM

Lenstar Artificial Crystal Meter

  • It is possible to accurately measure the curvature of the patient's cornea, the axial length, the anterior chamber depth, and other parameters to accurately calculate the refractive index of the artificial lens used in cataract surgery.
圖片_眼科儀器_乾眼症

Treatment of anterior blepharitis with AB Max™

AB Max™ features forward and backward movement, and its patented PULSE mode is specifically designed to remove even the most stubborn crusts and debris while gently massaging the eyelid margin to improve patient treatment results.

圖片_強脈衝光_治療乾眼症_E-Eye

Intense Pulsed Light (IPL)

E-Eye is a device that produces multi-colored pulsed light pulses (strong pulsed light or IPL) that can directly treat the meibomian glands in patients with dry eye syndrome. Meibomian gland dysfunction (MGD) is the main cause of dry eye discomfort. Treatment with E-Eye in several sessions can stimulate the function of these oil-producing glands and restore the lipid layer of the eye surface. The E-Eye delivers light pulses sorted uniformly to stimulate the meibomian glands in a sequence of adjusted pulses. Calculation of energy, spectrum, and time period is used to stimulate the meibomian glands.

It helps dry eye patients by reducing the abnormal blood vessels (capillary dilation) that secrete inflammatory chemicals around the eyelids, improving eyelid gland function and reducing the bacterial load around the eyes. The end result: more tears, healthier tear components, and fewer dry eye symptoms!

 

圖片_醫療儀器_LLLT面罩

 LLLT masks utilize medical-grade LEDs for light modulation, a light biostimulation technique that stimulates ATP (adenosine triphosphate) production by emitting light at specific wavelengths. It can also significantly heat the eyelids to temperatures recommended for intraocular thermal treatment. The combination of the increased cellular activity triggered by endogenous heat and external thermal heating helps stimulate glandular normalization. Such applications include eyelid gland dysfunction (MGD), dry eye or eyelid inflammation, and blepharitis.